ipv6RASendInterval

Value Type

decimal

Minimum Value

0

Default Value

10

Description

This parameter controls how often (in seconds) CDRouter will send IPv6 Router Advertisements on the WAN during IPv6 testing. If set to 0, CDRouter will not send periodic IPv6 Router Advertisements but will respond to Router Solicitations.